I/OLinc
Several options are available when configuring an I/OLinc on the ISY. These include:
Timeout (seconds) - Sets the length of time the relay will close when Momentary
is selected.
Program Lock - Disables Set Button programming.
Relay Follows Input - Sets Relay On when Sensor is On and Off when sensor if
Off.
Send X10 Send On (or Off) - Send X10 when the sensor changes.
Trigger Off - If the TrigOff bit is set, Close Switch sends an OFF and Open
Switch sends an ON. If the TrigOff bit is clear, Close Switch sends an ON and
Open Switch sends an OFF.
LED on TX - The LED will flash when the device sends Insteon commands.
Momentary: A - The relay will close momentary. If it is Linked while On it will
respond to On. If it is Linked while Off it will respond to Off.
Momentary: Look at Sensor - If the sensor is On the relay will close momentarily
when an On command is received. If the sensor is Off the relay will close
momentarily when an Off command is received.
Momentary: Both - On and Off both cause the relay to close momentary.
KeypadLinc
KeypadLincs show up as multiple nodes on the ISY (6 button or 8 button, depending on
which model KeypadLinc). When switching between 6 and 8 button modes on the
KeypadLinc, the device must be removed and re-added to the ISY.
Only the KeypadLinc’s primary load button can be controlled directly by the ISY
(through the Admin Console and ISY Programs). To control secondary buttons, create
a Scene containing the button and control the scene.
KeypadLincs support several unique options, such as:
- Manually Exclusive Buttons groupings of buttons so that one and only one button
in the group can be ON at any one time.
- Toggle Mode toggle a button to always stay ON or OFF (and only send the
respective command when pressed)
- LED Brightness adjust the KeypadLinc button LED brightness
Due to variations in KeypadLinc firmware, some configuration options may or may not
be available.
LampLinc
Most LampLincs will not act as controllers they will not notify the ISY or control other
linked devices if turned on or off locally (via the SET button or using load sensing).
LampLincs labeled v4.2 or higher (firmware v33+) should act as controllers.